Troubleshooting, Caution – Lincoln Electric RANGER 250 LPG IM931 User Manual

Page 32

Advertising
background image

E-2

TROUBLESHOOTING

E-2

RANGER 250 LPG

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your

Local Lincoln Authorized Field Service Facility

for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Major Physical or Electrical
Damage is Evident.

Engine will not "crank".

Engine will "crank" but not start.

Engine shuts down shortly after
starting.

Battery does not stay charged.

1. If all recommended possible

areas of misadjustment have
been checked and the problem
persists,

Contact your local

Lincoln Authorized Field
Service Facility.

1. Battery is low.

2. Loose battery cable connections.

3. Faulty engine starter motor.

4. “Battery Circuit” circuit breaker is

tripped.

1. LPG fuel cylinder empty.

2. Faulty fuel solenoid or faulty PC

board or ignition system.

1. Low oil level.

2. Faulty oil pressure switch or

other engine component.

3. Open rotor circuit.

1. Faulty battery.

2. Loose connections at battery or

alternator.

3. Faulty engine alternator or

charger module.

If all recommended possible areas
of misadjustment have been
checked and the problem persists,

Contact your local Lincoln
Authorized Field Service Facility.