Troubleshooting, Caution – Lincoln Electric RANGER 250 LPG IM931 User Manual

Page 35

Advertising
background image

E-5

TROUBLESHOOTING

E-5

RANGER 250 LPG

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your

Local Lincoln Authorized Field Service Facility

for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

The welding arc is “cold.” The
welding arc is not stable or is not
satisfactory. the engine runs nor-
mally. The auxiliary power is nor-
mal.

1. Make sure the MODE selector

switch is in the correct position
for the process being used. (For
example, CV-WIRE, PIPE, CC-
STICK.)

2. Make sure the electrode (wire,

gas, voltage, current etc.) is cor-
rect for the process being used.

3. Check for loose or faulty con-

nections at the weld output ter-
minals and welding cable con-
nections.

4. The welding cables may be too

long or coiled, causing an exces-
sive voltage drop.

If all recommended possible areas
of misadjustment have been
checked and the problem persists,

Contact your local Lincoln
Authorized Field Service Facility.

Advertising