E-4

TROUBLESHOOTING

E-4

RANGER 250 LPG

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your

Local Lincoln Authorized Field Service Facility

for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

No welding power output.

Welder has output but no control.

Wire feeder does not work when
control cable is connected to 14-
pin connector.

No auxiliary power.

1. Poor work lead connection to

work.

2. "Weld Terminals" switch in

wrong position.

3. Faulty PC board or welder alter-

nator.

1. Poor remote / control cable con-

nection to 6-pin or 14-pin con-
nector.

2. Faulty remote cable or faulty

wire feeder or wire feeder cable.

3. Faulty control potentiometer or

PC board.

1. Wire Feeder Power circuit

breaker open.

2. Faulty control cable.

3. Faulty wire feeder.

1. Open circuit breakers.

2. Faulty connections to auxiliary

receptacles.

3. GFCI tripped.

4. Faulty PC board or welder alter-

nator.

If all recommended possible areas
of misadjustment have been
checked and the problem persists,

Contact your local Lincoln
Authorized Field Service
Facility.