TROUBLESHOOTING GUIDE

Observe Safety Guidelines

detailed in the beginning of this manual.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con-
tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-
800-833-9353.

OUTPUT PROBLEMS
(SYMPTOMS)

POSSIBLE AREAS OF
MISADJUSTMENT(S)

RECOMMENDED
COURSE OF ACTION

FUNCTIONS PROBLEMS

The Multi-Source machine will not
shut off when the ON/OFF switch
is in the OFF position.

1. Remove all external loading to

the Multi-Source and then
carefully remove the input
power.

1. The ON/OFF power switch

may be faulty. See the Wiring
Diagram.

2. The input contactor may be

stuck closed. Perform the
Input Contactor Test.