MAIN TRANSFORMER (T1) VOLTAGE TEST (continued)

Reconnect Panel
Assembly

Input Contactor

TEST PROCEDURE

1. Disconnect main AC input power to the

machine.

2. Using a 3/8” nutdriver, remove roof and

sides of case cover.

3. Inspect the input contactor, reconnect

panel, and primary leads to the main trans-
former for loose or faulty connections. See
Figure F.5.

4. Carefully apply input power, turn on and

make sure the input contactor (1CR) ener-
gizes.

5. Carefully test with an AC voltmeter for the

proper main AC input voltage to the line
side of the input contactor (1CR). See
Wiring Diagram. See Figure F.5.

U to V

V to W

U to W

NOTE: If proper voltage is not present in any

or all of the three phases, check input
fuses and leads.

5. Test with an AC voltmeter for proper main

AC input voltage from the output side of

the input contactor (1CR). See Wiring
Diagram. See Figure F.5.

T1 to T2

T2 to T3

T1 to T3

a.

If the correct voltage is present, the
contactor is working properly.

b.

If the correct voltage is not present for
any or all of the three phases, the con-
tactor may be faulty. See Input
Contactor Test.

6. Test with an AC voltmeter for approximate-

ly 97 VAC from each of the six main trans-
former secondary leads to the common
buss connected to the negative output ter-
minal. See Figure F.6.

a.

If one or more of the above voltage
tests are incorrect, check for loose or
faulty wiring. If the wiring is good,
then the main transformer may be
faulty.

NOTE: A long wire with a clip or a long probe

may be required to reach the lower
middle lead.

FIGURE F.5. Input Contactor, Reconnect Panel, and Primary Leads to Main Transformer

Locations

T3

T2

T1

U

V

W

TOP VIEW