6. Carefully apply primary power and test for

the correct secondary voltages. See Table
F.1.

NOTE: If the correct main AC input power to
the Control Transformer is present, and the
secondary voltages are not correct, the Control
Transformer may be faulty. Replace.

TABLE F.1.

Primary H1 & H2

Voltage

Approximate Secondary

Voltage X1-X3

575 VAC

Approximate Secondary

Resistance (X1-X3)

460 VAC

380 VAC

34.50 VAC

28.50 VAC

0.5 Ohms

60 Ohms

Approximate Primary

Resistance (H1-H2)

X2-X3 Thermostat

0 Ohms

43.0 VAC

CONTROL TRANSFORMER (T2) VOLTAGE TEST