::= { GSW2690Time 4 }


GSW2690NTPTimeSync OBJECT-TYPE

SYNTAX INTEGER(0|1)

ACCESS

read-write

STATUS mandatory
DESCRIPTION

"Sync time from NTP Server. Get this oid always return zero.

Setting the Time Server and TimeZone before doing time sync.

Notice that time server must be correct!

value

range

(1|0):

1 - sync.

0 - do nothing."
-- @@ACTION

ruby_sys_time

::= { GSW2690Time 5 }


GSW2690DaylightSavingTime OBJECT-TYPE

SYNTAX INTEGER(-5..5)

ACCESS

read-write

STATUS mandatory
DESCRIPTION

"Get/Set the daylight saveing time.

value range is between -5 and 5. unit: hour. "

-- @@ACTION

ruby_sys_time

::= { GSW2690Time 6 }


GSW2690DaylightStartTime OBJECT-TYPE

SYNTAX DisplayString

ACCESS

read-write

STATUS mandatory
DESCRIPTION

"Get/Set the Start time of Daylight Saving.

The input format is 'MM/DD/HH',

and daylight saving start month can't equal end month.

example: month/day/hour 10/01/00

month: 01~12, day: 01~31, hour: 00~23 ."

-- @@ACTION

ruby_sys_time

::= { GSW2690Time 7 }


GSW2690DaylightEndTime OBJECT-TYPE

SYNTAX DisplayString

ACCESS

read-write

STATUS mandatory
DESCRIPTION

"Get/Set the End time of Daylight Saving.

The input format is 'MM/DD/HH',

and daylight saving start month can't equal end month.

example: month/day/hour 04/01/00

month: 01~12, day: 01~31, hour: 00~23 ."

-- @@ACTION

ruby_sys_time

::= { GSW2690Time 8 }


----------------------------------------------------------------------------------------