User manual – LevelOne ProCon GSW-2690 User Manual

Page 95

Advertising
background image

User Manual

Publication date: June, 2005

Revision A1

91

Per Trunking Group supports a maximum of 4 ready member-ports. Please

note that some decisions will automatically be made by the system while you are
configuring your trunking ports. Trunk Setting Rules are listed below:

Rule1: Maximum 3 groups are allowed

Rule 2: The members of each group cannot exceed more than 4 ports

Rule 3: Group 1 and 2 cannot exist member 25 and 26 port

Rule 4: Group 3 cannot exist member from 1 to 24 port

Advertising