Installation, Terminal strip 1 (t.s.1) terminal strip 2 (t.s.2) – Lincoln Electric CV-655 User Manual

Page 16

Advertising
background image

A-7

INSTALLATION

CV-655

A-7

TERMINAL STRIPS

Terminal strips are available behind the cover panel
on the lower case front to connect wire feeder control
cables that do not have a 14 Pin MS-type connector.
Refer to figure A.3 for the location of this cover panel.
These terminals supply the connections as shown in
the following Terminal Strip charts. See Auxiliary
Power Table for rating of circuit breaker in 115VAC
circuit. Remove a plug button from the terminal strip
cover and install an appropriate strain relief clamp for
the cable being used. NOTE: There are two work
sense lead connection points on the terminal strip.
Connect both the work sense lead #21 from the 14 pin
connector and #21 lead of the control cable to “-21”
when welding positive polarity or to “+21” when weld-
ing negative polarity.

TERMINAL STRIP 1 (T.S.1)

TERMINAL STRIP 2 (T.S.2)

Lead No.

Function

75

Output Control

76

Output Control

77

Output Control

1.

115VAC circuit is not present on IEC 974-1 models.

2.

As shipped from the factory Lead #21 from the 14 Pin connector is
connected to “-21” on the terminal strip. This is the configuration
for positive welding. If welding negative polarity, connect lead #21
to the “+21” connection point on the terminal strip.

Lead No.

Function

+21 Work

Connection

-21 Work

Connection

2

41

42 VAC

4 Trigger

Circuit

2 Trigger

Circuit

31 115

VAC

1

32 115

VAC

1