Diagrams, Cv-655 – Lincoln Electric CV-655 User Manual

Page 36

Advertising
background image

F-3

DIAGRAMS

F-3

CV-655

Above diagram shows electrode connected positive. To change polarity,

turn power off, reverse the electrode and work leads at the power

NEGATIVE

POSITIVE

32 31 2 4

GND

21

N.A.

N.D.

ELECTRODE CABLE

TO WORK

POWER SOURCE

Only qualified persons should install, use or

service this machine.

Do not operate with covers removed.

Disconnect power source before

servicing.

Do not touch electrically live parts.

CONTROL BOX

21

FOR CONTROL CABLE

WITH 14 PIN

MS-TYPE

PLUG CONNECTOR

OR

FOR CONTROL CABLE

WITH TERMINAL STRIP

LEAD CONNECTORS

CONTROL CABLE

S22978

N.B. & N.C.

14-PIN

RECEPTACLE

75

76

77

remote voltage sensing work lead may be ordered for this purpose.

If lead #21 is to be connected to

the terminal strip,

connect to the #21 terminal that matches

work polarity. This

connection must be changed whenever the

electrode polarity is

changed.

N.A. Welding cables must be of proper capacity for the current and

duty cycle of immediate and future applications.

Connect it directly to the work piece keeping it electrically separate form the welding work lead circuit and connection. For convenience, this extended #21 lead should be taped to the welding work lead. (If the length of work lead circuit is

short, and connections can be expected to be reliable, then

control cable lead #21 does not need to be extended and can be

directly connected to terminal #21 on the terminal strip. Note

that this is not the preferred connection because it adds error

N.D. Connect the control cable ground lead to the frame terminal

marked near the power source terminal strip. The power

source grounding terminal (marked and located near the power

source input power connections) must be properly connected to

electrical ground per the power source operating manual.

to the wire feeder voltmeter reading.)

N.F.

source.

Reverse the leads on the back of the ammeter and voltmeter

in the automatic control box.

Also refer to note N.F.

TO AUTOMATIC

EQUIPMENT

TO AUTOMATIC

CONTROL CABLE

physically suitable for the installation. An S16586-[LENGTH]

41

423

1

32

75

76

77

N.F.

21

-

21

+

REMOTE VOLTAGE SENSING LEAD

N.C. Tape up bolted connection if lead #21 is extended.

N.E. If a variable voltage board is present in the automatic controls,

the jumper lead on the VV board must be connected to pin "L" to

permit the inch down button to operate. This jumper, however,

will disable the cold starting/autostop feature of the automatic

controls, permitting only hot starting techniques to be used.

or from 14-pin receptacle using #14 AWG or larger insulated wire

N.B. Extend lead #21 from control cable with terminal strip connectors

10-30-98F

N.G.

Illustration does not necessarily represent actual position of

manual for more information.

N.G.

CONNECTION OF NA-3, LT-5 OR LT-7 TO THE CV-655, DC-655 OR DC-600 POWER SOURCE

appropriate output studs. Refer to power source operating

For proper setting of switches on power source,

see power source operating manual.