TROUBLESHOOTING

E-4

CV-655

Observe all Safety Guidelines detailed througout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

PROBLEMS

(SYMPTOMS)

PPOSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Variable or sluggish welding arc.

Machine will not shut off.

Output Control Pot not functioning in
“Local” control.

No output control in “Remote” con-
trol.

1. Make sure the welding cables are

sized correctly and the connec-
tions are tight.

2. Make sure the welding proce-

dures are correct.

1. The input power switch (SW1)

may be faulty.

2. The input contactor (CR1) may

be faulty.

1. Check the Local/Remote control

switch and associated leads.
See wiring diagram.

2. The machine output control

potentiometer may be faulty.
Also check associated leads.
See wiring diagram.

1. Output Control Switch in wrong

position.

2. Faulty Output Control Switch.

3. Faulty Remote Control Pot.

4. Leads or connections open in con-

trol circuit. (#75, #76, #77)

If all recommended possible areas
of misadjustments have been
checked and the problem persists,
contact your local Lincoln
Authorized Field Service Facility.