Installation, Work cable, Gun and cable assemblies – Lincoln Electric LN-7 GMA WIRE FEEDERS User Manual

Page 27: Gun cable connections, A-20

Advertising
background image

A-20

INSTALLATION

LN-7 & LN-7 GMA

A-20

WORK CABLE

Connect a work lead of sufficient size and length
(Table A.2) between the proper output stud on the
power source and the work. Be sure the connection to
the work makes tight metal-to-metal electrical contact.
Poor work lead connections can result in the grounding
lead protector being activated.

TABLE A.2 – WORK LEAD SPECIFICATIONS

Copper Work Cable Size, AWG

Current 60%

Up To 50 Ft

50 Ft-100 Ft

Duty Cycle

(15.2 m

2

)

(15.2-30.4 m

2

)

300 Amps

0 (53 mm

2

)

00 (67 mm

2

)

400 Amps

00 (67 mm

2

)

000 (85 mm

2

)

500 Amps

00 (67 mm

2

)

000 (85 mm

2

)

600 Amps

000 (85 mm

2

)

0000 (107 mm

2

)

GUN AND CABLE ASSEMBLIES

The LN-7 and LN-7 GMA can be used with several
guns. In most cases, Lincoln guns and cables are
shipped assembled, ready to weld. Use the gun and
cable assembly for the electrode type (solid,
Outershield , or Innershield) and electrode size to be
used. Refer to the Accessories Section for different
gun types.

GUN CABLE CONNECTIONS

Lay the cable out straight. Insert the connector on the
welding conductor cable through the large hole in the
front panel of the LN-7 and into the brass conductor
block on the front of the gearbox. Refer to Figure A.18.
Make sure it is all the way in and tighten the hand
wheel. Keep this connection clean and bright. Connect

FIGURE A.18 – GUN CABLE CONNECTIONS.

AMPHENOL

CONNECTOR

GUN CABLE

ASSEMBLY

CONDUCTOR

BLOCK

the control cable amphenol plug into the mating 5-
cavity receptacle on the front of the control section
below the nameplate.

If using the K489-1 Fast-Mate Adapter, install per the
S19389 instructions included with the kit.

Advertising