INSTALLATION

LN-7 & LN-7 GMA

A-22

SHIELDING GAS HOOKUP

(LN-7 GMA

or LN-7 with Optional K494 Gas Solenoid
Installed)

Gas under pressure is explosive. Always keep gas
cylinders in an upright position and to the
undercarriage or a stationary support. See
American National Standard Z-49.1, “Safety In
Welding And Cutting”, published by the American
Welding Society.

------------------------------------------------------------------------

Customer must provide a cylinder of shielding gas, a
pressure regulator, a flow control valve, and a hose

from the flow valve to the gas inlet fitting of the LN-7
GMA or the K494 Gas Solenoid Valve Kit installed on
the LN-7. Install per Figure A.20 and the following:

1. Connect the supply hose from the gas cylinder

flow valve outlet to the 5/8-18 female inert gas
fitting on the back panel of the LN-7.

2. Install the barbed fitting and union nut to the

5/8-18 female inert gas fitting on the front of the
LN-7. Connect 3/16 in. (4.8 mm) I.D. gas hose
from the gun to the barbed fitting.

When the gun is to be removed, this fitting can be
easily detached by loosening the union nut.

FIGURE A.20 – SHIELDING GAS HOOKUP.