Power Information

Power Requirements

Voltage:

95 - 250 Volts AC, 3-wire single phase, auto-ranging

Frequency:

47-63

Hz

Operating Current:

300 mA @ 120 V

Power Consumption:

40

Watts

(maximum)

Fuse Rating:

1.6A,

250

Volts

Power Supply Cord

Cord type:

3 conductors, 1.0 mm2 minimum conductor size
(approximately 18 AWG)

Rated for:

250 Volts AC, 10 Amps

Length: 3.0

meters

Environmental Limitations

Temperature

Operating range:

5° to 50° C (41° to 122° F)

Storage range:

-40° to 66° C (-40° to 151° F)

Max temp. change/hr:

20° C (36° F)

Rapid temperature changes may affect operation. Therefore, do not operate the ETS
near heating or cooling devices, large windows, or doors that open to the outdoors.

Altitude

Operating maximum:

2.4 km (8,000 ft)

Storage maximum:

9.1 km (30,000 ft)

If operating the ETS above 2.4 km (8000 ft.), decrease the operating temperature
rating by 1° F for each 1000 ft.

Relative Humidity

Operating range:

10% to 90% noncondensing, 40% to 60%
recommended

Storage range:

10% to 90% noncondensing