Diagnostic Error Code

FRU/Action

170-199-XXX Voltage Sensor(s) test failed, cause
unknown

1. See "Undetermined problems" on page 65

2. Flash the system and re-test. See "Flash update

procedures" on page 467

3. Replace component under function test

170-250-XXX 170-251-XXX Voltage Sensor(s) Voltage
limit error

1. Power supply

2. System board

170-254-XXX Voltage Sensor(s) Voltage Regulator
Module error

1. Voltage Regulator Module (VRM)

2. Microprocessor

3. System board

175-000-XXX Thermal Sensor(s) Test Passed

No action

175-0XX-XXX Thermal Sensor(s) failure

1. Flash system

2. System board

175-195-XXX Thermal Sensor(s) Test aborted by user

Information only Re-start the test, if necessary

175-196-XXX Thermal Sensor(s) test halt, error threshold
exceeded

1. Press F3 to review the log file

2. Re-start the test to reset the log file

175-197-XXX Thermal Sensor(s) test warning

1. Make sure the component that is called out is

connected and/or enabled. See Chapter 6 "Using
the Setup Utility" on page 39

2. Re-run test

3. Replace the component that is called out in warning

statement

4. Replace the component under test

175-198-XXX Thermal Sensor(s) test aborted

1. If a component is called out, make sure it is

connected and/or enabled

2. Flash the system and re-test. See "Flash update

procedures" on page 467

3. Go to "Undetermined problems" on page 65

175-199-XXX Thermal Sensor(s) test failed, cause
unknown

1. See "Undetermined problems" on page 65

2. Flash the system and re-test. See "Flash update

procedures" on page 467

3. Replace component under function test

175-250-XXX 175-251-XXX Thermal Sensor(s) limit error

1. Check fans

2. Check Power supply voltages

3. Microprocessor

4. System board

185-000-XXX Asset Security Test Passed

No action

185-XXX-XXX Asset Security failure

1. Flash system

2. System board

185-278-XXX Asset Security Chassis Intrusion

1. Assure Asset Security Enabled

2. C2 Cover Switch

3. System board

201-000-XXX System Memory Test Passed

No action

Chapter 7 Symptom-to-FRU Index