Lenovo 9354 User Manual

Page 66

Advertising
background image

Diagnostic Error Code

FRU/Action

201-XXX-XXX System Memory error

1. Replace the memory module called out by the test

2. System board

202-000-XXX System Cache Test Passed

No action

202-XXX-XXX System Cache error

1. Cache, if removable

2. System board

3. Microprocessor

206-000-XXX Diskette Drive Test Passed

No action

206-XXX-XXX Diskette Drive error

1. Diskette Drive Cable

2. Check power supply voltages

3. Diskette drive

4. System board

215-000-XXX CD-ROM Drive Test Passed

No action

215-XXX-XXX CD-ROM Drive error

1. CD-ROM Drive Cable

2. Check power supply voltages

3. CD-ROM drive

4. System board

217-000-XXX Hard Disk Drive Test Passed

No action

217-25X-XXX 217-26X-XXX Hard Disk Drive (IDE) error

1. Hard Disk Drive Cable

2. Check power supply voltages

3. Reseat the hard disk drive cable

4. Hard Disk drive (IDE)

5. System board

217-28X-XXX 217-29X-XXX Hard Disk Drive (SCSI) error

1. Hard Disk Drive Cable

2. Check power supply voltages

3. Reseat the hard disk drive cable

4. Hard Disk drive (SCSI)

5. SCSI adapter card

6. System board

220-000-XXX Hi-Capacity Cartridge Drive Test Passed

No action

220-XXX-XXX Hi-Capacity Cartridge Drive error

1. Remove the Hi-Capacity Cartridge Drive and

re-test the system

301-XXX-XXX Keyboard error

1. Keyboard

2. Check and test mouse

3. System board

301-000-XXX Keyboard Test Passed

No action

302-000-XXX Mouse Test Passed

No action

302-XXX-XXX Mouse error

1. Mouse

2. Check and test Keyboard

3. System board

303-000-XXX Joystick Test Passed

No action

303-XXX-XXX Joystick error

Remove the Joystick and re-test the system

60

ThinkCentre Hardware Maintenance Manual

Advertising