TROUBLESHOOTING

E-3

Observe all Safety Guidelines detailed throughout this manual

OUTPUT PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Major physical or electrical damage
is observed when cover wrap-around
is removed.

The machine is dead - no output.

No output but the fan operates nor-
mally.

1. The input power switch must be

in the ON position.

2. Make sure the input voltage is

correct for the machine.

3. If the machine is set for single-

phase operation, inspect to
assure that the WHITE and
BLACK leads are connected
properly and the RED lead is not
connected and is insulated.

4. Check that the input voltage set-

up switch and jumper

A

(the

reconnect auxiliary jumper) are in
the proper position for the input
voltage being applied. Refer to

Input Voltage Reconnect
Procedure

in the Installation

Chapter.

5. Check continuity of the 0.6-amp

slow blow fuse located on the
reconnect panel.

1. If the machine has not been used

for a long time and is connected
for 380 VAC or higher, the
capacitors may need

condition-

ing

. See Input Filter Capacitor

Conditioning.

2. The machine may be overheated.

Check the thermal indicator light.
Wait for the machine to cool and
the thermostats to reset.

If all recommended possible areas of
misadjustment have been checked
and the problem persists,

Contact

your local Authorized Field Service
Facility.

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, con-
tact your local authorized field service facility for technical troubleshooting assistance before you proceed.