Troubleshooting, Caution – Lincoln Electric IM803-B User Manual

Page 22

Advertising
background image

ES 275i

E-5

TROUBLESHOOTING

E-5

Observe all Safety Guidelines detailed throughout this manual

OUTPUT PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

No output - Main input fuses open,
indicating excessive current draw.

The machine operates normally
when connected for 200 - 230VAC
input. There is no output when the
machine is connected to 380VAC or
higher.

1. Inspect input leads for possible

shorts or grounds or mis-connec-
tions.

2. Install new fuses and reapply

power. If fuses open again, con-
sult a Authorized Field Service
Facility.

1. Check the input voltage and input

voltage reconnect procedures.
See

Installation Section

of this

manual.

If all recommended possible areas of
misadjustment have been checked
and the problem persists,

Contact

your local Authorized Field Service
Facility.

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, con-
tact your local authorized field service facility for technical troubleshooting assistance before you proceed.

CAUTION

Advertising