Troubleshooting, Caution – Lincoln Electric IM803-B User Manual

Page 21

Advertising
background image

ES 275i

E-4

TROUBLESHOOTING

E-4

Observe all Safety Guidelines detailed throughout this manual

OUTPUT PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Output turns on momentarily, then
switches off and repeats cycle.

Remote output control not
functioning. The machine operates
normally on LOCAL control.

1. Check the input voltages and

reconnection procedures. Make
sure the input voltage is correct
for the machine. See

Input

Voltage Reconnect Procedure

.

2. Check or replace remote control

device. (If used)

1. Make sure the Local/Remote

switch (S3) is in the REMOTE
position.

2. The remote control device may

be faulty. Replace.

3. The Local/Remote switch must

be in the LOCAL position unless
a remote control device is
attached to the remote
receptacle.

If all recommended possible areas of
misadjustment have been checked
and the problem persists,

Contact

your local Authorized Field Service
Facility.

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, con-
tact your local authorized field service facility for technical troubleshooting assistance before you proceed.

CAUTION