A-1

INSTALLATION

POWER WAVE 405

A-1

TECHNICAL SPECIFICATIONS -

POWER WAVE 405

INPUT AC VOLTAGE & DC OUTPUT

OUTPUT CABLES, CONNECTIONS AND LIMITATIONS

Product

Ordering

Input AC

Rated DC Output Output

Weight Dimensions

Name Information Voltage

Amps/Volts/Duty Cycle

Range

with Cord

HxWxD

50/60 Hz

(continuous)

350A / 34V / 60%

14.7”x12.5”x

Power

200-220/

3 Phase

27.8”*

Wave

K 2152-2 380-400/ 320A / 33V / 60%

AMPS

86.5lbs

(373x318x

405

415

1 Phase

5-425

(37.4 kg) 706*)mm

60/50 Hz

275A / 31V /100%

1 Phase

300A / 32V / 100%

* Includes

3 Phase

handles

* Overall Length Including Handle, 21.6” (549mm) without handle.

Select the output cable size based upon the following chart.
Cable sizes for Combined Length of Electrode and Work Cable (Copper) 75C rated:

DUTY CYCLE

CURRENT

LENGTH UP 61m (200 FT)

61-76m (200-250 FT)

100%

275

2/0

2/0

60%

350

2/0

2/0

INPUT CURRENT

2. When operating on these inputs, the line cord should be changed to an input conductor of 6 AWG or larger.

1. Not rated is indicated by 4-x's in the box on the rating plate

Recommended Fuse Sizes Based On The U.S. National Electrical Code And Maximum Machine Outputs

Input 50/60 Hz

Output

Recommended

Voltage

Phases

300Amps@

350Amps@

Line Cord

Size Fuse Size Notes

32Volts(100%)

34Volts(60%)

AWG SIZES

200

3

41

48

6

80A

Note 2

230

3

37

48

6

80A

Note 2

380

3

23

28

8

50A

400

3

22

27

8

50A

415

3

22

26

8

50A

Voltage

Phases

275Amps@

320Amps@

Line Cord

Size Fuse Size Notes

31Volts(100%) 33Volts(60%)

200

1

----

----

---

-----

Note 1

220

1

64

82

4

125A

Note 2

380

1

44

55

6

80A

Note 2

400

1

40

50

8

80A

415

1

38

48

8

80A

Advertising