The steps for operating the Power Wave will vary
depending upon the options installed in the user inter-
face (control box) of the welding system. The flexibility
of the Power Wave system lets the user customize
operation for the best performance.

First, consider the desired welding process and the
part to be welded. Choose an electrode material,
diameter, shielding gas and process (GMAW, GMAW-
P, etc.)

Second, find the program in the welding software that
best matches the desired welding process. The stan-
dard software shipped with the Power Waves encom-
passes a wide range of common processes and will
meet most needs. If a special welding program is
desired, contact the local Lincoln Electric sales repre-
sentative.

To make a weld, the Power Wave needs to know the
desired welding parameters. The Power Feed (PF)
family of feeders communicate settings to the Power
Wave through control cable connection. Arc length,
wire feed speed, arc control, etc. are all communicat-
ed digitally via the control cable.

WELDING ADJUSTMENTS

All adjustments are made on the system component
known as the User Interface (Control Box), which con-
tains the switches, knobs, and digital displays neces-
sary to control both the Power Wave and a Power
Feed wire feeder. Typically, the Control Box is sup-
plied as part of the wire feeder. It can be mounted
directly on the wire feeder itself, the front of the power
source, or mounted separately, as might be done in a
welding boom installation.

Because the Control Box can be configured with many
different options, your system may not have all of the
following adjustments. Regardless of availability, all
controls are described below. For further information,
consult the Power Feed wire feeder instruction manu-
al.

WFS / AMPS:

In synergic welding modes (synergic CV, pulse, pulse
on pulse, GMAW) WFS (wire feed speed) is the domi-
nant control parameter, controlling all other variables.
The user adjusts WFS according to factors such as
weld size, penetration requirements, heat input, etc.
The Power Wave then uses the WFS setting to adjust
its output characteristics (output voltage, output cur-
rent) according to pre-programmed settings contained
in the Power Wave.

B-3

OPERATION

POWER WAVE 405

B-3

5. Internal POWER CIRCUIT BREAKER: Protects 115

volt AC circuit.

6. LEAD CONNECTOR (SENSE LEAD)
7. DIAGNOSTIC CONNECTOR (RS-232)
8. WIRE FEEDER RECEPTACLE (5-PIN)
9. NEGATIVE TWIST- MATE TERMINAL
10. POSITIVE TWIST- MATE TERMINAL

NOMINAL PROCEDURES

The Power Wave is designed to operate with 3/4"
electrode stick-out for CV and Pulse processes.

FRINGE PROCEDURES

Excessively short or long electrode stick-outs may
function only on a limited basis, if at all.

MAKING A WELD

The serviceability of a product or structure utiliz-
ing the welding programs is and must be the sole
responsibility of the builder/user. Many variables
beyond the control of The Lincoln Electric
Company affect the results obtained in applying
these programs. These variables include, but are
not limited to, welding procedure, plate chemistry
and temperature, weldment design, fabrication
methods and service requirements. The available
range of a welding program may not be suitable
for all applications, and the build/user is and must
be solely responsible for welding program selec-
tion.
------------------------------------------------------------------------

10

4

6

1

3

2

5

7

8

9

CASE FRONT LAYOUT

POWER WAVE 405

WARNING