INSTALLATION

POWER WAVE 405

A-6

FIGURE A.2

Simple System

SYSTEM SET-UP

Basic Rules

Each group is required to have one user interface.

No group may have more than one user interface.

Each group can have up to seven Feed Heads.

Exception: Group 3 is limited to a maximum of six
Feed Heads.

Each system has only one power source. For net-

work purposes, the PS belongs to Group 3, which is
why group 3 is only allowed 6 feed heads in addition
it

s user interface.

No two feed heads can have identical Group and

Feed Head numbers.

Group and Feed Head ID numbers must be set on

the appropriate dipswitches at each node. Consult
the appropiate Power Feed Wire Feeder Instruction
Manual for specific details regarding dipswitch set-
tings.

Feed head

0

not allowed. Exception: Simple sys-

tem ignores all ID numbers, therefore

FH0

will

function.

Each node must be connected to the Linc-Net com-

munication network. The order of connection is not
important, as each node is identified by it

s unique

Group and Feed Head ID number as defined on it

s

dipswitches. See Figures A.2 thru A.5.

Group and Feed
Head ID numbers are
ignored in a simple
system.