OFF

SW position

VS/VD

Unit Number Setting

A rotary switch is placed on the front panel. It specifies the WJ-MP204C unit number in a PS

Data protocol system, or camera

unit numbers in a Camera Communication Protocol system.

8

Setting the unit number

1 Turn off the power switch of the unit.
2 Use a screw driver to rotate the UNIT switch so that the arrow comes to the number you wish.
3 Turn on the power switch.

Notes:

• The unit number can be specified in the setup menu when the UNIT switch is set to "0."
• Position #9 is not allowed to be set, because it is reserved.
• Specify a unique number for each unit when connecting more than one unit in a data communication chain.

DIP Switch Setting

A 6-bit DIP switch mounted on the rear panel specifies communication mode and sync setup. The default position is marked
with an asterisk * in the table below.

Bit 1 specifies the setup for synchronization. Refer to page 23 VS/VD IN and OUT for details.
Bit 2 is reserved.
Bit 3 specifies the communication protocol used in the system.
Bit 4 is reserved.
Bit 5 specifies the termination in the communication chain.
Bit 6 specifies RS-485 communication mode conducted via DATA port or RS-485 terminal. Set it to 4-line when PS

Data is

used.

1

OFF

ON

2

3

4

5

6

Function

ON

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

RS-485 mode

Line termination

Reserved

Protocol

Reserved

Sync setup

4-line full duplex*

Off

Fixed to OFF*

PS

Data*

Fixed to OFF*

THROUGH*

2-line half duplex

On*

Not used

Camera Communication

Not used

0

9

8

7

6

5

4

3

2

1

UNIT