Alarm mode setup

1. Move the cursor to ALARM MODE to select ON or OFF

with the [–] or [+] button, then press SET. The default
setting is ON.

ON :

Opens a submenu shown below.

OFF:

Alarm mode is disabled.

The ALARM MODE sub menu appears.

1-1. Move the cursor to MONITOR SPOT to select ON

or

OFF with the [–] or [+] button, then press SET. The
default setting is ON

.

This setting specifies whether to change the monitor
image when an alarm operates.

ON :

Image display on the monitor changes to that

of the alarm activated channel.

OFF:

Image display will not change even when an

alarm operates.

The MONITOR SPOT sub menu appears.

1-2. In this setup, the relation is established between four

alarm channels and four camera channels, along with
the preset positions to which the camera moves when
the alarm operates.

1-2-1. Move the cursor to a channel of CAM. NO with the

[D] or [C] button.

1-2-2. Select a CAM. NO with the [–] or [+] button, then

press the [C]. The cursor moves to PRE. The
default setting is that the same numbers are
assigned to both alarm channel and camera chan-
nel.

1CH:

Camera input 1 will be displayed when the

respective alarm operates.

2CH:

Camera input 2 will be displayed.

3CH:

Camera input 3 will be displayed.

4CH:

Camera input 4 will be displayed.

1-2-3. Select a PRE (preset position number) with the [–]

or [+] button, then press the [C].

1-2-4. Repeat above steps for other alarm channels.
1-2-5. Press the ESC to return to the ALARM MODE menu.

2. Move the cursor to ALARM DISPLAY. Select ON or OFF

with the [–] or [+] button. The default setting is ON.
Alarm display “ALARM

***

” on the monitor is enabled

or disabled while an alarm is in operation. “

***

” is the

alarm channel number.

ON:

Enabled.

OFF:

Disabled.

3. Move the cursor to SITE ALARM. Select ON or OFF with

the [–] or [+] button. The default setting is ON.
A site alarm (motion detection) generated by a camera
is accepted or ignored.

ON:

Enabled.

OFF:

Disabled.

4. Move the cursor to TERM. ALARM (terminal alarm).

Select ON or OFF with the [–] or [+] button. The default
setting is ON.
An alarm input to the rear terminal is accepted or
ignored.

ON:

Enabled.

OFF:

Disabled.

5. Move the cursor to ALARM OUTPUT. Select an output

duration with the [–] or [+] button. The default setting is
10S (seconds).
The output status is supplied to the terminals on the
rear. The output is reset along with the activated alarm
according to this setup.

EXT:

The output is reset when a reset input is supplied

to the rear panel or the alarm reset button is
pressed on the front panel.

1S-5MIN:

The output is reset when the preset duration

elapses.

OFF:

No output.

6. Move the cursor to ALARM DATA. Select an output time

with the [–] or [+] button. The default setting is 1S (sec-
ond).
The unit notifies the connected System Controller (must
be set to Unit #1) of the alarm activation once every
period preset by this setup.

OFF:

No notification.

0S:

Notification is made immediately.

1S:

Notification is made once every 1 second.

5S:

Notification is made once every 5 second.

7. Press the ESC to go back to the SYSTEM menu.

ALARM MODE

MONITOR SPOT ON
ALARM DISPLAY ON
SITE ALARM ON
TERM.ALARM ON
ALARM OUTPUT 10S
ALARM DATA 1S

MONITOR SPOT

ALARM CAM NO. PRE
1 1CH -
2 2CH -
3 3CH -
4 4CH -