Chapter 8: Internal Devices
Calibration

116

8580/8590 Vehicle-Mount Computer User Manual

3. In the Software License Agreement window, choose I accept all of the

terms of the above License Agreement, and then tap Next.

4. In the Select Controller dialog, choose serial (RS/232) and tap Next.
5. In the Serial Configuration dialog, choose COM4 and 9600 Baud and

tap Next.

6. Deselect the option on the Configuration Complete dialog and close by

tapping Finish.

7. Two Files Needed windows will appear querying the path to the

tsufiltr.sys file.

8. Select Browse to navigate to the installation folder indicated above,

then choose the Serial folder and tap OK.

9. Confirm the final message Setup is now complete by tapping OK.

The computer does not need to be restarted.

8.5.1.2

Calibration

The touchscreen must be calibrated so that it functions correctly.

1. Start the touch configuration tool under Start/Programs/Hampshire

TSHARC Control Panel.

2. Choose the Calibration tab and tap the Touch field.
3. Once calibration is complete, finish by tapping Accept.
4. Choose the Click Settings tab and choose Enable right click emula-

tion. Enter the following values:
Right-Click Area + Double-Click Area each to 13;
Right-Click Delay + Double-Click Delay each to the third line.

5. Exit the tool with OK.