troublesHootinG

symptom

probable cause

remedy

No output

Source or amplifier
not turned on .

Check source or amplifier and fix
as required .

Audio input not con-
nected or no output
from source .

Check rCA connection and
signal integrity, fix or replace as
required .

Bi-amp/parallel switch
set incorrectly for ap-
plication .

Set Bi-amp/parallel switch to
correct setting (see Crossover
connections and input switch set-
ting, Bi-amplified connections to
crossover, or Bi-wire connections
to crossover) .

Protection circuit
activated .

Turn down volume, protection
circuit will automatically reset .

Speaker wires not
connected .

Check speaker wires and fix or
replace as required .

Audio cycles on
and off

Speaker damaged .

Check system with known work-
ing speaker and fix or replace as
required

Thermal protection
engaged .

Check that amplifier has ad-
equate ventilation, check speaker
impedance load

Loose or poor audio
connections .

Check rCA power and speaker
connections and fix or replace as
required .

Distorted output

Preamp volume set
to high exceeding
maximum capability of
amplifier .

Check volume or preamp and
adjust appropriately .

Impedance load to
amplifier too low .

Check speaker impedance load, if
below 1 ohm rewire the speakers
to achieve a higher impedance .

Bi-amp/parallel switch
set incorrectly for ap-
plication .

Set Bi-amp/parallel switch to
correct setting (see Crossover
connections and input switch set-
ting, Bi-amplified connections to
crossover, or Bi-wire connections
to crossover) .

Shorted speaker
wires .

Check speaker wire connections
and fix or replace as needed .