9. WIRING DETAILS

X1 - 9-pin D-type socket for connection to the High Performance
desk (LBB 5800)

Pin No.

Function

1

+12 V power supply from the desk
(fused at 1 AT)

2

not connected

3

not connected

4

RS 422 serial int. B (extra 220 Ohm)

5

0 V

6

+ 12 V power supply from the desk
(fused 1 AT)

7

not connected

8

RS 422 serial int. A (extra 220 Ohm)

9

0 V

screening not connected

X2 - 9-pin D-type socket for external alarm functions

Pin No.

Function

1

make

- relay contact RE1

2

break

- relay contact RE1

3

middle

- relay contact RE2

4

make

- relay contact RE3

5

break

- relay contact RE3

6

middle

- relay contact RE1

7

make

- relay contact RE2

8

break

- relay contact RE2

9

middle

- relay contact RE3

screening not connected

Relays can only be used on voltages not exceeding
34 VDC and a current of 1 A maximum.

2.5 m long interconnecting cable between desk and FCP
wiring details:
(9-pin D-type on FCP

-

25-pin D-type of Desk)

Pin No. (9-pin)

Wire

Pin Nr. (25-pin)

1 (+12V)

blue

23 (+12V)

6 (+12V)

red

25 (+12V)

5 (0V)

black

17 (0V)

9 (0V)

grey

24 (0V)

4 (RS422 B)

green

14 (RS422 B)

8 (RS422 A)

yellow

16 (RS422 A)

2 )

others not

3 )

not connected

connected

7 )

Cable length between the LBB 5800 Desk and the LBB 6005 FCP may be extended to a distance of approx. 1000 metres.

Bear in mind that if the Desk is separated from the FCP, that speech communication with the PST is via the microphone/speaker in the
Desk.

DP 6000 DIGITAL PAGING SYSTEM

INSTALLATION INSTRUCTION 69

December 1997

Page 10/15

FCP Rear view

X2

X1

Advertising