Philips DP 6000 User Manual

Page 11

Advertising
background image

PS 6000 and DP 6000 SYSTEM WIRING

Installation details of the various units in the PS 6000 system can be found in the relevant Installation Instructions:(see contents)

INSTALLATION INSTRUCTION 69

DP 6000 DIGITAL PAGING SYSTEM

Page 11/15

December 1997

1

16

1

16

1

16

1

16

1

16

1

16

1

16

PSU*

PSU*

PSU*

1

2

3

4

5

6

7

8

PSU*

PSU*

TX

RX

DESK

Control desk
LBB 5800/00

* The number of power supply
units (PSU) required is
determined by the size of,the
system and the distance the
various units are apart LBB 5934/00
12 V - 1A

LBB 6010/6110
fitted with
LBB 6015

UHF or
VHF
Transmitter

FCP type LBB 6005/00.
Each FCP can cater for
up to 16 transceivers.
A max. of 31 FCPs can
be used off one desk.
FCP consumes 180 mA
therefore extra PSUs
are required.

LBB 6151/01

LBB 6151/00

Data/audio output to the transmitter

3 x external relay outputs
from each FCP

Data/audio output to the transmitter

4-wire transmitter switching line

System earth

Audio/DP 6000 code input (talk-back)

Audio/DP 6000 code input (talk-back)

Pins 9 and 10 - sync. lines
Pins 15 and 16 - monitoring

4-wire squelch line

+ 12V power supply

Ext. alarm
contacts
(pins 9 -16)

FCP

DP 6000 PAGING LINE

Plug

Socket

16-pin Hirschmann