2-19

Features

SCSI-2 Hard Drive Bays

The right side of the system contains six bays for 3 1/2-
inch SCSI-2 hard drives and a hot-swap backplane (see
Figure 2-6). The backplane supports six drives. The
backplanes require an 80-pin single connector
attachment (SCA) connector on the drives you install.

A drive carrier is required as part of the hot swap
implementation. A 3 1/2-inch peripheral between 1.0
and 1.6 inches high can be accommodated in each
carrier. A drive is mounted in the carrier with four
fasteners, and the carrier is retained in the chassis by
a locking handle.

Figure 2-6. SCSI-2 Hard Drive Bays

Six bays for SCSI drives

(EMI panel and exterior door
shown open)

A fault light on the front panel board gives a general
indication that there has been a fault on a hot-swap
drive. Each drive has a set of three lights to indicate
the fault or other status: power-on (green LED),
activity (green LED), or fault (yellow LED).