2-25

Features

Table 2-5. Power LED Indicators

LED

Status

Description

Response

DC-Power

Off

Green

Power is off

Power is on

None required - normal

None required - normal

Alarm

Off

Amber

No alarm

Power failure

Abnormal Power temperature

Power FAN alarm

DC-Power alarm

None required - normal

Replace Power supply

Clean air passages

Replace Power supply

Replace Power supply

Figure 2-9. Power Supply Module Features

B

E

C

D

F

G

A

A Power cage

B Main power switch

C LED: DC ON (Green)

D LED: Alarm (Amber)

E Power supply modules

F Basic power slots

G Redundant power slot

Hot Swap FAN

The system has five hot swappable fan modules (six
fans). The failed fan module can be easily removed or
replaced without turning power off. Each fan module
has a fan alarm LED and each fan is redundant in
configuration. If one fan fails, its associated fan
changes its rotating speed to high. Table 2-6 lists the
fan redundant pairs. Figure 2-10 shows the fan
features from the front of the chassis and Figure 2-11
shows the fan features from the rear of the chassis.