-11-

15. G/L Signal 75-ohm ON/OFF Switch (75

ON/OFF)

A terminating switch for G/L signals at Items 16 and
17.

16. G/L VBS/HD Input Connector (G/L IN - VBS/HD)

Signals synchronized with the reference signal are to
be supplied to this connector when the camera is to
be synchronized with the reference signal. VBS/BB,
VS and HD signals are to be automatically deter-
mined.

17. G/L VD Input Connector (G/L IN - VD)

Same as Item 16 except that VD signal is to be sup-
plied when input signal at Item 16 is HD.

LENS MOUNTING

Lenses of any make can be mounted on the camera as
long as they are equipped with a 1/2” standard bayonet.

1. Mounting

Rotate the lens fixing ring knob counterclockwise and
remove the lens mount cap. Mount the lens on the
camera and rotate the lens fixing ring knob clockwise
in order to fix the lens securely. Then connect the lens
cable to the IRIS Connector on the back panel of the
camera.

* Use the lens extension cable WV-CA12T12 (6”/15cm)

if your lens cable is too short.

Lens fixing ring knob