A. Configuration Options

8784-A2-GB20-30

February 2001

A-9

Table A-4.

System Options

DSL Mode

Possible Settings: LTU, NTU
Default Setting: LTU

Controls whether the unit is configured as a control unit or tributary unit.

LTU – The unit is configured as a control unit (Line Termination Unit).

NTU – The unit is configured as a tributary unit (Network Termination Unit). This unit will
request its IP address from the LTU during establishment of the PPP link.

NOTE: Changing this option will reset the card.

Test Timeout

Possible Settings: Enable, Disable
Default Setting: Enable

Allows tests to end automatically. The feature should be enabled when the unit is remotely
managed, so that control can be regained after a test is accidentally executed.

Enable – Loopback and pattern tests end when test duration is reached.

Disable – Tests run until manually terminated from the Network Tests screen or remotely
(network initiated tests). Refer to

Running Network Tests

in Chapter 5,

Testing.

Test Duration (min)

Possible Settings: 1 – 120
Default Setting: 10

Number of minutes for a test to be active before automatically ending.

T

Test Duration (min) option appears when Test Timeout is enabled.

1 – 120 – Amount of time in minutes for a test to run before terminating.

Telco Initiated Loopback

Possible Settings: Enable, Disable
Default Setting: Enable

Determines if the unit will respond to Telco loopback commands on the DSX-1 interface.
See

Telco-Initiated Tests

in Chapter 5,

Testing.

Enable – The unit will respond to Telco loopback commands.

Disable – The unit will not respond to Telco loopback commands.

Remote Telco Line Loopback

Possible Settings: Enable, Disable
Default Setting: Disable

Determines if the unit will perform a Telco initiated loopback on just the local unit or if the
loopback will be performed on the remote DSL unit. See

Telco-Initiated Tests

in Chapter 5,

Testing.

Enable – The loopback will be in the remote unit.

Disable – The loopback will be local.