Paradyne 8784 User Manual

Page 96

Advertising
background image

B. Standards Compliance for SNMP Traps

B-4

February 2001

8784-A2-GB20-30

The tests that affect the enterpriseTestStart, enterpriseTestStop, and the
variable-bindings are different for each particular interface. Diagnostic tests are
only supported on the physical T1 network and user data port interfaces. The
specific tests and variable-bindings are described in the following table:

Interface

enterpriseTestStart/Stop
Variable-Bindings

Possible Cause

DSL Network

T

ifIndex (RFC 1573)

T

ifAdminStatus (RFC 1573)

T

ifOperStatus (RFC 1573)

T

ifType (RFC 1573)

T

ifTestType (RFC 1573)

The following objects control tests
in SNMP-managed devices:

– noTest – Stops the test in

progress.

– testLoopLLB – Initiates a Local

Loopback.

– testLoopRLB – Initiates a

Remote Loopback.

– testSendMon511 – Initiates a

Send and Monitor 511 test.

– testSendLLBUp – Initiates an

LLB Up message to the
remote unit.

– testSendLLBDown – Initiates

an LLB Down message to the
remote unit.

T

enterpriseTest Start – Any
one of the following tests is
active on the interface:

– Line Loopback

– Repeater Loopback

– Remote Line Loopback

– Send and Monitor 511

T

enterpriseTest Stop – No
tests currently running on
the interface.

DSX-1

T

ifIndex (RFC 1573)

T

ifAdminStatus (RFC 1573)

T

ifOperStatus (RFC 1573)

T

ifTestType (RFC 1573)

The following objects control tests
in SNMP-managed devices:

– noTest – Stops the test in

progress.

– testLoopExternalDTE

T

enterpriseTest Start – Any
one of the following tests is
active on the interface:

– Data Terminal

Loopback

– Repeater Loopback

– testLoop RLB – initiates

a Repeater Loopback

– testLoop DTLB –

initiates a DSX-1 DTE
Loopback

T

enterpriseTest Stop – No
tests currently running on
the interface.

Advertising