Menu settings – Panasonic AW-RP400E User Manual

Page 30

Advertising
background image

Pan/Tilt Head Controller AW-RP400

29 (E)

Menu settings

MONITOR SELECT setting

This menu item is used to select the controller used to switch the images of the AW-RC400’s MONITOR2 output when the
AW-CB400 remote operation panel and a second AW-RP400 have been connected to this AW-RP400 controller and the
AW-RC400 cable compensator is used.
By setting the master AW-RP400 and slave AW-RP400, the camera images which have been selected by the controller given
in the table below are output as the AW-RC400’s monitor output.

BUZZER setting (OFF/ON)

This menu item is used to select ON or OFF for the buzzer inside the controller. The buzzer does not sound at the OFF
setting.
The buzzer sounds when the CALL button has been pressed or when a tracing memory operation (record, play or change) is
started, suspended or ended.

AUTO RUN setting (START No., END No., INTERVAL)

This menu item enables the presets of the pan/tilt head to be repeated automatically.

START No. (1 to 50):

This sets the first number of the preset to be repeated.

END No. (1 to 50):

This sets the last number of the preset to be repeated.

INTERVAL (1s to 30s):

This sets the stop time at the preset position.
Up to 30 seconds can be set in 1-second increments for the stop time.

OPERATE (STOP/RUN): When RUN is selected, the presets from the START No. to STOP No. are played repeatedly;

when STOP is selected, operation stops.
When the PAN/TILT lever is operated, STOP is selected automatically, and operation stops.

SD CARD setting

The menu setting data of this controller, the preset memory data of the pan/tilt heads and the setting data of the cameras can
be stored on SD memory cards.
If the MENU button is pressed while STORE is displayed, the setting data is stored on the SD memory card.
If the MENU button is pressed while LOAD is displayed, the data stored on the SD memory card is called, and the settings
are loaded into the controller, pan/tilt heads and cameras.

The tracing memory data is not stored.

AW-RP400 menu setting

AW-RC400

Master unit

Slave unit

MONITOR1

MONITOR2

MON2 = CB400

MONITOR2 = setting disabled

Master RP400

Master CB400

MON2 = SLAVE

MONITOR2 = RP400

Master RP400

Slave RP400

MONITOR2 = CB400

Master RP400

Slave CB400

When the cable compensator has been connected to the slave AW-RP400, the images selected by the slave
AW-RP400 are output to MONITOR1 on the AW-RP400 and the images selected by the slave AW-CB400 are output
to MONITOR2 regardless of this setting.

Advertising
This manual is related to the following products: