Roll Unit AW-RL400

44 (E)

ENGLISH

Specifications

Pan/tilt head connector:

Connected to pan/tilt head using cable supplied

Performance:

Maximum load-bearing capability: 4 kg
Rotary range: 380 degrees (approx. ±190 degrees)
Maximum operating speed: 60 degrees/sec.
Repeatability: Less than ±1 degree

Noise level: Less than ???

Ambient operating temperature: 0°C to +40°C

Storage temperature:

–20°C to +60°C

Ambient operating humidity:

30% to 90% (no condensation)

Dimensions (W

!

H

!

D):

205

!

198

!

260 mm

Weight:

Approx. 3.9 kg

Finish:

AV ivory paint (colour resembling Munsell 7.9Y6.8/0.8)

Supply voltage:

DC 24V

Power consumption: Approx. 24W

Installation

1

indicates safety information.

5

Attach the camera mounting plate to the roll unit in a way contrary to the procedure
of removing it in step

3

.

Camera mounting plate’s screws