English – Pitco Frialator Gas Fryer 65 User Manual

Page 19

Advertising
background image

1-11

with water later.

Filling the fryer with oil is described in 2.1. To perform the calibration check detailed below you will
need a digital thermometer.

a. Place the tip of the thermometer in the shortening approximately 1" above the temperature

sensors.

b. Set the thermostat at 325°F and wait for the temperature reading on the thermometer to rise.

As the temperature rises toward 325°F watch the thermometer closely.

c. If the shortening temperature reaches 350°F and the burners DO NOT turn off, turn the

thermostat down. Keep lowering the thermostat setting until the burners go out.

CAUTION

If the burners do not turn off at the lowest thermostat setting, the thermostat
could be defective. Contact your representative immediately.

d. Let the fryer cycle 4 to 6 times before checking the temperature. Compare the thermometer

temperature against the thermostat setting. If the values are more than 5°F apart, calibrate
the thermostat using the appropriate calibration procedure in this manual.

1.5.6 Thermostat Calibration

a. Place the tip of the thermometer in the shortening approximately 1" above the temperature

sensors.

b. Set the Thermostat to 325°F and wait for the temperature reading on the thermometer to rise.

c. Let the fryer cycle 4 to 6 times to ensure that the temperature has stabilized. Compare the

thermometer temperature against the thermostat setting. If the values are more than 5°F
apart, calibrate the thermostat using the appropriate calibration procedure.

ENGLISH

Advertising
This manual is related to the following products: