Adjustment

$

Reset to 3200K or 5600K white balance

When the white balance setting is set to either “3200K” or
“5600K” the white balance will be automatically set to the
colour temperature 3200K or 5600K, respectively.

$

Black balance adjustment

• Close the lens.

If the motor drive lens is controlled from the camera, the
lens is automatically closed when the black balance is
adjusted.

• When the camera is used without a RCU or RCB, R/B

pedestal adjustment of painting setting will be
automatically reset to ±0 after setting the black balance.
(painting setting in only User Mode.)

[ADJUSTMENT by CAMERA]
Press the YES/ABC switch for over 2 seconds and the black
balance will be set automatically in 10 seconds.

In user mode, black balance fine adjustment can be
performed with the red pedestal/blue pedestal setting after
setting the black balance.

[ADJUSTMENT with the RCU (RCB, hybrid control panel)]
Set the AUTO set switch to ABC and the black balance will
be automatically set. While the system is being set, the auto
warning indicator (LED) blinks and it goes out when the
black balance setting is completed. If the lamp remains lit,
ABC should be tried again.

Minimize the carrier wave using
the red & blue gain controls

Waveform for white
balance set chart

YES/ABC switch

AUTO set switch