English – Panasonic AW-E860L User Manual

Page 39

Advertising
background image

G

Electronic Shutter Synchro Scan Setting
[Synchro Scan: 50.24Hz to 15.63kHz]
This setting is possible only when Electronic Shutter
setting is at S/Scan.
Horizontal bar noise can be reduced by synchro-scan
adjustment in shooting workstation scenes, for example.

For luminance settings at each shutter speed and
synchro-scan shutter speed, refer to the table below.

H

CCD Read Out Mode Setting
[V Resolution: Normal, Fine]

Normal: Normal image. (CCD storage will be by field

storage.)

Fine:

Vertical resolution increases. (Vertical resolution
is raised without increasing residual images by
frame storage and Electronic shutter.)
Normal is recommended for general use
because sensitivity will decrease at the Fine
setting.

I

PC Control Access Speed Setting [Baud Rate:
1200bps, 2400bps, 4800bps, 9600bps]
Select a communication speed in controlling the camera
from the computer.

J

Component Output Setting
[Signal Select: RGB, Y/Pr/Pb, Y/C]
This enables RGB, Y/Pr/Pb or Y/C to be selected as the
component signals which are to be output from the I/F
REMOTE connector.

K

Aspect Ratio Selection [Aspect Ratio: 16:9, 4:3]
Aspect ratio can be selected from 16:9 or 4:3.

L

Fan Setting [Fan SW: OFF, Auto]

OFF: Select this setting to stop the fan when its

operating sound is found to be bothersome in a
studio or other such environment.

Auto: The temperature is detected automatically, and

the fan starts operating when the temperature
exceeds approx. 35°C.
Under normal circumstances, the “Auto” setting is
used.

- 38 (E) -

ENGLISH

Shutter Speed

Synchro-scan

Required luminance ratio

OFF

1

1/120

120.2 Hz

2

1/250

250.0 Hz

4

1/500

492.2 Hz

8

1/1000

984.4 Hz

16

1/2000

1.969 kHz

32

1/4000

3.938 kHz

64

1/10000

7.875 kHz

160