RS-232C Adjustment Mode

1.6 GET Commands

What are GET commands?

• GET commands are for outputting TXD such as adjustment data from the internal microcomputer of the plasma

display to a PC.

• Adjustment data and other information is output as ASCII code.

Note

Command names are given inside brackets < >.

• Data output format

Notes

• A GET command is invalid when no ID is assigned to the set.

• A GET command is invalid when a wildcard (*) is used as par of the ID when sending the command.

1) <GST> (GET STATUS)

Order

Data Contents

Size

Remarks

1

Display data

3 Byte

See below

2

Power data

3 Byte

See below (The third character is sub input.)

3

Input function data (main)

3 Byte

Input data when GST is received (INPUT1 to 5 is displayed as IN1 to 5.)

4

Input function data (sub)

3 Byte

Sub input data when GST is received

Note 3)

(INPUT 1 to 5 is displayed as IN1 to 5.)

5

Screen size data

1 Byte

See below

6

2-screen display

1 Byte

0: OFF (1 screen)

1: 2-SCREEN

2: PinP (lower right)

3: PinP (upper right) 4: PinP (upper left)

5: PinP (lower left)

6: PoutP

7

FUNCTIONAL LOCK data

1 Byte

0: LOCK OFF 1: BUTTONS LOCK 2: IR LOCK

3: IR&BUTTONS LOCK 4: MEMORY LOCK

8

Dummy data

3 Byte

(3-digit number)

9

Temperature data 2

3 Byte

(Internal temperature: Reference value) °C

Note 1)

10

Temperature data 3

3 Byte

(External temperature: Reference value) °C

Note 1)

11

Serial

15 Byte

12

Dummy data

3 Byte

(3-digit number)

13

Dummy data

3 Byte

14

HOURMETER

5 Byte

Displays the time.

15

Check sum

2 Byte

STX (02hex)

Data

Data

····

Data

ETX (03hex)

Checksum

Display data

First character Generation data: 4 (fixed)

Second character Inch data: 4 (43 inch), 5 (50 inch)

Third character Destination data: M (fixed)

Power data

First character Power state & signal state

Second character PN (POWER ON & normal signal input)

PL (POWER ON & no input)

PO (POWER ON & OUT OF RANGE signal input)

SN (Normal standby)

SW (Standby by POWER MANAGMENT)

SS (Standby by SD or PD)

Third character Sub input signal state during multi-screen display

Note 2)

N (Normal signal input) L (No input)

O (OUT OF RANGE signal input)

Screen size data

First character 0; Dot by Dot or PARTIAL 1; 4 : 3 2; FULL or FULL1080i

3; ZOOM 4;CINEMA 5;WIDE 8;FULL1035i 9; UNDERSCAN

NOTE 1) During Standby and immediately after POWER ON, the proper value is not output. If this occurs, wait a moment

after POWER ON then 'get' the data. The temperature data is output as a reference (the values are not
guaranteed values). Normally, refer to temperature data 3.

NOTE 2) During Standby and during 1-screen display, the unit outputs dummy data (symbol).