RS-232C Adjustment Mode

7 Check Sum
The Check Sum is data to which 2-Byte ASCII code is added to a data group that is returned by a GET command.

STX

02 (hex)

2 Byte

3 Byte

03 (hex)

ID

GET command

ETX

STX

02 (hex)

GET command

3 Byte

Data

*Byte

Check sum

2 Byte

ETX

03 (hex)

PC side

Set side

.

Example) Check Sum value that is added when the GET command [GAA] returns the following 6-Byte data

GET command

GAA

Data (6 Byte)

100128

Data

100128

Check sum

0B

ETX

03 (hex)

Check sum

xx (before calculation)

Data group (ASCII)
+ check sum

47 41 41 31 30 30 31 32 38

when these values are added the result is 1F5 (hex)

as the data format, OB is converted to ASCII code and sent

The following data is output from the plasma display side.

xx, where xx is 0B (hex), is added to 1F5 so the last two digits are 00 (in this case 200)

STX

02 (hex)

GET command

GAA

The data group is put into binary code
one character at a time then displayed.
Only the last two digits are displayed.

7 Examples of check sum applications
Example 1) When the data is missing 1 Byte

47 41 31 30 30 32 38

check sum [OB (hex)] and the calculated [3C (hex)] do not match

Data

100 (missing data) 28

Check sum

0B

ETX

03 (hex)

STX

02 (hex)

GET command

GAA

data group is calculated according to rules set by a PC application
when these values are added, the result is 1C4 (hex)

value xx, where xx is 3C (hex), is added to 1C4 such that the last
two digits are 00 (in this case 200)

Since they do not match, the PC application repeats the GET command
and retrieves the data again.

Example 2) When 1 Byte of data in the data is unreadable

47 41 31 30 33 30 32 38

check sum [OB (hex)] and the calculated [09 (hex)] do not match.

Data

100328

Check sum

0B

ETX

03 (hex)

STX

02 (hex)

GET command

GAA

data group is calculated according to rules by a PC application
when these values are added, the result is 1F7 (hex)

value xx, where xx is 09 (hex), is added to 1F7 such that the last
two digits are 00 (in this case 200)

Since they do not match, the PC application repeats the GET command
and retrieves the data again.

*The returned data group is in capital English letters. Please keep this in mind when introducing it into

the binary code.

.