Precautions, 19 4.0 precautions – Pioneer PDP-505CMX Plasma Display Panel RS-232 User Manual

Page 19

Advertising
background image

19

4.0 Precautions

1) If the power shuts down and stays OFF for a long period of time, an internal problem may have occurred (broken

part, etc.).

Turn OFF the main power switch on the plasma display then wait 1 to 2 minutes and try turning the power ON again.

If the power goes OFF again, the display requires service.

If the display operates normally, continue to use it.

2) When an image (still image, telop, etc.) is shown on the screen for a long period, there is a possibility that the

image could be burned in (not able to be removed). Manage this situation by making necessary changes in the

video software, projection method, system configuration, etc.

3) The following kinds of input signals could cause inferior image quality.

• Video signal that has been dubbed (copied) repeatedly

• Copyright-protected video signals

• Scrambled cable TV signals

• Signals with a sync signal and video signal that are extremely out of phase

4) The fan starts operating when the surrounding temperature is greater than 35 °C. The fan's rpm becomes faster as

the temperature increases; this is normal.

5) Screen-saver function (still image detection)

When an image having little to no motion such as a photograph or PC screen is displayed continuously, the brightness

slightly drops. To protect the plasma panel, the screen-saver function detects images with little to no motion then

automatically adjusts the brightness. This dimming is not an indication that the panel is failing.

Time until the screen-saver function operates:

• Normal-operation mode/menu mode: Approximate 3 minutes after the power is turned ON or after the input is

switched.

7 Self-diagnosis Function

When there is an connection or operation error, a message displays on the screen. After reading the contents of the

error message, refer to the chart below before checking the unit.

Precautions

Error Message

CAUTION

OUT OF RANGE or

CAUTION

UNSUPPORTED SIGNAL or

SIGNAL NG

WARNING

THERMAL ALERT

SHUT DOWN (

∗∗)

WARNING

FAN FAILURE

SHUT DOWN (

∗∗)

ERROR

INVALID KEY ENTRY

SHUT DOWN (

∗∗)

Remedy

¶ The current signal input is not supported by the unit. Check the table of supported

input signals on pages 140 - 145 and change the output signal setting.

¶ The current signal input is not supported when FRC is set to MODE2 or MODE3.

Check the FRC settings on page 208.

¶ Turn OFF the main power.
¶ Check whether the surrounding temperature is high.
¶ If the cooling vents on the display are blocked, remove the obstacles blocking the

vents.

¶ There is a problem with the fan. Immediately turn OFF the power and contact the

Pioneer service center or dealer.

¶ An invalid operation was attempted. Check the input signals, connections and

settings.

¶ Turn the main power OFF, wait 1 or 2 minutes and turn the power ON again. If the

problem still persists, remove the power plug from the outlet and contact a Pioneer

service center or dealer.

(

∗∗): Numbers are displayed here.

Advertising