DETERMINE VENTING SIZE AND DISTANCE:

It is recommended that the vent system be installed with a minimum of three (3’) of vertical
rise above the appliance exhaust port.

Equivalent Vent Length (EVL) is the method of determining vent sizes and lengths, that takes into account the
effect of different component parts on air flow.

STEP 1 To help you determine the correct size and/or run, simply fill in the chart below.

Pellet Venting

Component

# of Elbows

OR feet of Pipe

Multiply by

Equivalent

Feet

Component

Equivalent

90 Degree or Tee

X

5

45 Degree

X

3

Horizontal Pipe

X

1

Vertical Pipe

X

.5

Total

Equivalent


Step 2

Ensure the Total Equivalent is or is

less than 30.

Step 3

Use the Sizing Chart to determine

the proper venting size according to

the Total Equivalent and the

Altitude above sea level.

NOTE:

In some cases it may be necessary

to contact Dansons Customer

Service personal to determine

acceptable

venting

configurations

and altitude adjustments

1-877-303-3134.







The diagram to the right will help to
give you a visual reference.


0 1 2 3 4 5 6 7 8 9 10

10

20

30

Altitude in Thousands of Feet

Eq

u

iv

a

le

n

t P

ip

e

L

e

ng

th

in

F

e

e

t

3 or 4 Inch Diameter Pipe

4 Inch Diameter Only

Use

Diameter “PL” Vent

If venting outside of
shaded area.

4”

0’

0’

5’

5’

10’

10’

15’

20’

25’

30’

33’

Vent must have a support
bracket every 5’ when on
the exterior wall.

Vent height and run

exceed the distance

shown in the un-shaded
region of chart.

must

not

To achieve optimum
performance, keep vent runs
as short as possible.
Especially on horizontal
installations.

Use or

Diameter

“PL” Vent, if venting in
shaded area.

3” 4”

Maximum venting height is 33’.

Maximum horizontal offset is 10’.

Use the Equivalent Vent Length
Chart to determine proper
combination of component parts.

PelPro Home & Shop Heater www.pelprostoves.com 11