Reestanding, Nstallation, Main floor - vertical – PelPro Wood Pellet Stoves HSPP2 User Manual

Page 19: Hearth stove - existing reline

Advertising
background image

19

Walkout Basement or Main Floor

Basement or Main Floor

1

Pipe Adapter

Clean Out Tee & Cap

Tee Support Bracket

Horizontal Rain Cap

2

3

4

5

6

7

8

90 Deg Elbow

36” Pipe Length

12” Pipe Length

12” Adjustable Pipe Length

Wall Thimble

9

1

Pipe Adapter

Clean Out Tee & Cap

Tee Support Bracket

Horizontal Rain Cap

2

3

4

5

6

7

8

90 Deg Elbow

36” Pipe Length

12” Pipe Length

12” Adjustable Pipe Length

Wall Thimble

9

10

24” Pipe Length x 2

10

1

2

3

4

5

6

7

8

Ground Level

Floor / Ceiling

12”

12”

9

9

Tube of RTV Silicone
Roll of Foil Tape

3/8” Stainless Self-Tapping
Screws x 27

2” Wood Screws x 10

Options

Tube of RTV Silicone
Roll of Foil Tape

3/8” Stainless Self-Tapping
Screws x 21

2” Wood Screws x 10

1

2

3

4

5

6

7

8

9

These styles of installation are highly recommended, due to possible backpressure in the exhaust caused by
airflow around the outside of the structure, snow build-up, or power failure, etc.. These designs will improve
venting performance and provide natural draft to help evacuate smoke from the appliance in case of power
failure.

Follow the same basic steps in locating your appliance, attaching the exhaust system and outside air intake to
your stove as the previous examples.

1

2

3

4

5

6

7

8

Main Floor - Vertical

1

Pipe Adapter

Clean Out Tee & Cap

3 x 60” (15’) Pipe Length

Tee Support Bracket

Ceiling Support / Firestop Spacer

Roof Flashing

Storm Collar

Vertical Rain Cap

2

3

4

5

6

7

8

Tube of RTV Silicone

Roll of Foil Tape

3/8” Stainless Self-Tapping
Screws x 27

2” Wood Screws x 10

8”

16”

Optional

Metal Plate

1

2

3

4

5

6

7

8

9

24”

Hearth Stove - Existing Reline

1

Pipe Adapter

Single Wall Stainless Steel
Clean Out Tee & Cap

Storm Collar

Vertical Rain Cap

2

3

4

5

6

7

8

Hi Heat Insulation

“All Fuel” Stainless Steel
Flex Liner

Roof Flashing

Liner Support

Dripless Connection

9

Tube of RTV Silicone

Roll of Foil Tape

3/8” Stainless Self-Tapping
Screws x 27

6”

PL Vent Length

10

10

Outside Air may be obtained from a suitable duct passing through the
ash clean-out opening.

Ensure the chimney top is properly sealed to prevent intrusion of
weather and down drafts with suitable flashings, collars, and sealants.

F

F

REESTANDING

REESTANDING

I

I

NSTALLATION

NSTALLATION

. . . C

. . . C

ON

ON

T

T

PelPro Home & Shop Heater www.pelprostoves.com 19

Advertising
This manual is related to the following products: