188

Ikôn Rugged PDA (Windows CE 5.0) User Manual

Chapter 5: Configuration
Decoded (ISCP)
Code 93

5.14.3.10 Code 93

Enabled
Set this parameter to on to enable “Code 93”.

Minimum Length
Minimum lengths for the bar code can be set from 0 to 255. The length of a code refers to
the number of characters (i.e., human readable characters), including check digit(s).

Field Size/Chars
Refer to “Field Size/Chars” on page 170 for details.

5.14.3.11 Codabar

Enabled
Set this parameter to on to enable “Codabar”.

Start/Stop Transmit
Codabar can use the following sets of characters as start and stop characters:

a, b, c, d
A, B, C, D
a, b, c, d, /, t, n, *, e
DC1, DC2, DC3, DC4

Thus, when a set is chosen, the first and last digits of a Codabar message must be one of
those characters and the body of the message should not contain these characters. Setting
this parameter to Not Transmitted strips the start and stop characters from this bar code.

CLSI Library System
When enabled, spaces are inserted after characters 1, 5, 10 in the 14-character label (used in
the USA by libraries using the CLSI system).

Check Digit Verification
When enabled, this parameter checks the integrity of a symbol to ensure it complies with a
specified algorithm—either USS (Uniform Symbology Specification) or OPCC (Optical
Product Code Council).

Transmit Check Digit
If the check digit is to be transmitted with the data, this parameter must be enabled.

Advertising