17 telepen – PYLE Audio IKON RUGGED 7505-BTSDCMHC25 User Manual

Page 204

Advertising
background image

192

Ikôn Rugged PDA (Windows CE 5.0) User Manual

Chapter 5: Configuration
Decoded (ISCP)
Telepen

Check Digit Verification
The available options for this parameter are Disabled and MOD 10 Check. “Check Digit
Verification” uses the specified algorithm of the option you've chosen to ensure the integrity
of the symbol data before transmitting. If the data does not contain that algorithm, the data is
not transmitted.

Transmit Check Digit
If the check digit is to be transmitted with the data, this parameter must be enabled.

Set Length L1, Set Length L2, And Set Length L3
Lengths for “Discrete 2 of 5” can be set from 0 to 255. The length of a code refers to the
number of characters (i.e., human readable characters), including check digit(s).
Double-tapping on these parameters displays dialog boxes where you can define the code
length that will be recognized by your scanner.

Length Mode
You can chose to set L1 as Minimum Length or L1,L2,L3 as Fixed Length.

Field Size/Chars
Refer to “Field Size/Chars” on page 170 for details.

5.14.3.17 Telepen

Enabled
Set this parameter to on to enable “Telepen”.

Format
This parameter allows you to set the bar code character format to either ASCII or Numeric.

Minimum Length
Minimum lengths for the bar code can be set from 0 to 255. The length of a code refers to
the number of characters (i.e., human readable characters), including check digit(s).

Field Size/Chars
Refer to “Field Size/Chars” on page 170 for details.

Advertising