Pride Mobility JAZZY 1170 XL PLUS User Manual

Page 42

Advertising
background image

42

www.pridemobility.com

Jazzy 1170 XL Plus

V I I . O P E R A T I O N

Off-board Charger/Programming Socket

You may use an off-board charger to charge the power chair batteries through the 3-pin socket located on the front
of the Europa. If you use an off-board charger, the charger current should not exceed 8 amps. Contact your
authorized Pride Provider for more information.

NOTE: The socket may also be used for reprogramming the Europa. Contact your authorized Pride
Provider for more information.

Sleep Mode (If Enabled)

The power chair controller features a sleep mode. Sleep mode is a built-in circuit that will automatically shut off the
main power if the joystick is not moved in any direction for a period of time. This time factor is programmed into the
controller. To restore power and continue, push and key on the keypad.

Europa Error Codes

The system status light is displayed within the on/off key. This light is lit if the system is turned on. It also flashes in
groups called trouble codes, to indicate system faults. The table below identifies the individual trouble codes. If
your keypad displays one of these codes, contact your authorized Pride Provider.

TROUBLE CODE

SEQUENCE

DIAGNOSIS

SOLUTION

•—•—•—

DX module fault

See your authorized Pride Provider.

••—••—••—

DX accessory fault

See your authorized Pride Provider.

•••—•••—

Left motor (or connection) fault

Check left motor wiring.

••••—••••—

Right motor (or connection) fault

Check right motor wiring.

•••••—•••••—

Left park brake fault

Check motor/brake wiring.

••••••—••••••—

Right park brake fault

Check motor/brake wiring.

•••••••—•••••••—

Low battery fault

Check that the battery wiring is secure.

•••••••—•••••••—

Over voltage fault

Check that the battery wiring is secure.

•••••••—•••••••—

CANL fault

See your authorized Pride Provider.

•••••••—•••••••—

CANA fault

See your authorized Pride Provider.

•••••••—•••••••—

Stall timeout

Turn unit on, then off.

•••••••—•••••••—

Module mismatch

See your authorized Pride Provider.

NOTE: You must turn the controller off and then on again to reset the controller, even if the source of
the fault is removed/corrected.

In the event of a fault, the system status light displays diagnostic indications. Faults are encoded as follows: one (for
a low battery voltage fault) to twelve (module mismatch) and are displayed by the light flashing the number of times
prescribed by the fault code. The flash sequence (one to twelve) is followed by a long off period (2 seconds). If
more than one fault exists, then the fault having the highest priority is indicated. The controller must be turned off
and then on again even if the source of the fault is removed. If you cannot resolve the problem, contact your
authorized Pride Provider.

Advertising