Types, Rating – Panasonic TN Relay User Manual

Page 2

Advertising
background image

TN

TYPES

1. Standard PC board terminal

Standard packing: Tube: 50 pcs.; Case: 1,000 pcs.

2. Self-clinching terminal

Standard packing: Tube: 50 pcs.; Case: 1,000 pcs.
Note: Types (“-3” to the end of part No.) designed to withstand strong vibration caused, for example, by the use of terminal cutters, can also be ordered.

However, please contact us if you need parts for use in low level load and low thermal power.

RATING

1. Coil data
1) Single side stable

2) 1 coil latching

Contact

arrangement

Nominal coil

voltage

Single side stable

1 coil latching

2 coil latching

Part No.

Part No.

Part No.

2 Form C

3V DC

TN2-3V

TN2-L-3V

TN2-L2-3V

4.5V DC

TN2-4.5V

TN2-L-4.5V

TN2-L2-4.5V

5V DC

TN2-5V

TN2-L-5V

TN2-L2-5V

6V DC

TN2-6V

TN2-L-6V

TN2-L2-6V

9V DC

TN2-9V

TN2-L-9V

TN2-L2-9V

12V DC

TN2-12V

TN2-L-12V

TN2-L2-12V

24V DC

TN2-24V

TN2-L-24V

TN2-L2-24V

48V DC

TN2-48V

Contact

arrangement

Nominal coil

voltage

Single side stable

1 coil latching

2 coil latching

Part No.

Part No.

Part No.

2 Form C

3V DC

TN2-H-3V

TN2-L-H-3V

TN2-L2-H-3V

4.5V DC

TN2-H-4.5V

TN2-L-H-4.5V

TN2-L2-H-4.5V

5V DC

TN2-H-5V

TN2-L-H-5V

TN2-L2-H-5V

6V DC

TN2-H-6V

TN2-L-H-6V

TN2-L2-H-6V

9V DC

TN2-H-9V

TN2-L-H-9V

TN2-L2-H-9V

12V DC

TN2-H-12V

TN2-L-H-12V

TN2-L2-H-12V

24V DC

TN2-H-24V

TN2-L-H-24V

TN2-L2-H-24V

48V DC

TN2-H-48V

Nominal coil

voltage

Pick-up voltage

(at 20

°C

68

°F

)

Drop-out voltage

(at 20

°C

68

°F

)

Nominal operating

current

[

±10%] (at 20°C

68

°F

)

Coil resistance

[

±10%] (at 20°C

68

°F

)

Nominal operating

power

Max. allowable voltage

(at 20

°C

68

°F

)

3V DC

75%V or less of

nominal voltage*

(Initial)

10%V or more of

nominal voltage*

(Initial)

46.7mA

64.3

140mW

150%V of

nominal voltage

4.5V DC

31.1mA

145

5V DC

28.1mA

178

6V DC

23.3mA

257

9V DC

15.5mA

579

12V DC

11.7mA

1,028

24V DC

8.3mA

2,880

200mW

48V DC

6.25mA

7,680

300mW

120%V of

nominal voltage

Nominal coil

voltage

Set voltage

(at 20

°C

68

°F

)

Reset voltage

(at 20

°C

68

°F

)

Nominal operating

current

[

±10%] (at 20°C

68

°F

)

Coil resistance

[

±10%] (at 20°C

68

°F

)

Nominal operating

power

Max. allowable voltage

(at 20

°C

68

°F

)

3V DC

75%V or less of

nominal voltage*

(Initial)

75%V or less of

nominal voltage*

(Initial)

33.3mA

90

100mW

150%V of

nominal voltage

4.5V DC

22.2mA

202.5

5V DC

20mA

250

6V DC

16.7mA

360

9V DC

11.1mA

810

12V DC

8.3mA

1,440

24V DC

6.3mA

3,840

150mW

All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.