4. Electrical life (DC load)

Tested sample: TN2-12V, 10 pcs.
Condition: 1 A 30 V DC resistive load, 20 cpm

Change of pick-up and drop-out voltage

Change of contact resistance

5. Coil temperature rise

Tested sample: TN2-12V
Point measured: Inside the coil
Ambient temperature: Room temperature (25

° to

26

°C), 70°C

(77

° to 79°F), 158°F

Max.

Max.

Min.

Min.

No. of operations,

×10

4

0

10

20

30

40

50

60

70

80

90

100

5

10

15

20

Ratio against the rated voltage %V

Pick-up voltage

Drop-out voltage

5

10

15

20

No.of operations,

×10

4

Contact resistance,m

0

10

20

30

40

50

60

70

80

90

100

Terminal No.2–3–4

Terminal No.7–8–9

0

Coil applied voltage, %V

Temperature rise,

°C

80

90

100 110 120 130 140 150

10

20

30

40

50

60

70

Carrying current
0 A (Room temp.)
1 A (Room temp.)
0 A (70

°C)

1 A (70

°C)

6. Set/reset time characteristics

Tested sample: TN2-L2-12V, 5 pcs.

7. Ambient temperature characteristics

Tested sample: TN2-12V, 5 pcs.

8-(1). Malfunctional shock (single side stable)

Tested sample: TN2-12V, 6 pcs.

Max.

Min.

0

1

2

3

4

5

6

80

90

100

110

120

Coil applied voltage, %V

Set and reset time, ms

Set time

Reset time

20

0

x

x

Pick-up voltage

40

60

80

–10

–20

–40

10

20

30

40

Drop-out

voltage

Ambient

temperature,

°C

–10

–20

–30

–40

Variation

ratio, %

Y

Z

,

Z

X

,

X

,

X

X

Z

Z

,

Y

Y ,

980m/s

2

980m/s

2

980m/s

2

980m/s

2

980m/s

2

980m/s

2

Y

,

Deenergized condition
Energized condition

8-(2). Malfunctional shock (latching)

Tested sample: TN2-L2-12V, 6 pcs.

9-(1). Influence of adjacent mounting

9-(2). Influence of adjacent mounting

Y

Z

,

Z

X

,

X

,

X

X

Z

Z

,

Y

Y ,

980m/s

2

980m/s

2

980m/s

2

980m/s

2

980m/s

2

980m/s

2

Y

,

Deenergized condition
Energized condition

ON

ON

ON

OFF

OFF

OFF

Inter-relay distance , mm

inch

Rate of change, %

Rate of change, %

0

5

.197

–10

10

0

–10

0

10

Pick-up voltage

Drop-out voltage

ON

ON

ON

OFF

OFF

OFF

Inter-relay distance , mm

inch

Rate of change, %

Rate of change, %

0

5

.197

0

20

10

–10

0

10

Pick-up voltage

Drop-out voltage

10. Actual load test (35 mA 48 V DC wire spring relay load)

Tested sample: TN2-12V, 5 pcs.

Change of pick-up and drop-out voltage

Change of contact resistance

No. of operations,

×10

4

Ratio against the rated voltage, %V

Max.

Min.

Max.

Min.

0

10

10

20

30

40

50

60

70

80

90

100

20

30

40

50

Pick-up voltage

Drop-out voltage

No. of operations,

×10

4

Max.

Min.

0

10

10

20

30

40

50

60

70

80

90

100

20

30

40

50

Contact resistance, m

Terminal No. 2–3

All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.