Reference data – Panasonic TN Relay User Manual

Page 3

Advertising
background image

TN

3) 2 coil latching

*Pulse drive (JIS C 5442-1986)

2. Specifications

Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the

actual load. (SX relays are available for low level load switching [10V DC, 10mA max. level])

*2 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT.

REFERENCE DATA

Nominal coil

voltage

Set voltage

(at 20

°C

68

°F

)

Reset voltage

(at 20

°C

68

°F

)

Nominal operating

current

[

±10%] (at 20°C

68

°F

)

Coil resistance

[

±10%] (at 20°C

68

°F

)

Nominal operating

power

Max. allowable voltage

(at 20

°C

68

°F

)

Set coil

Reset coil

Set coil

Reset coil

Set coil

Reset coil

3V DC

75%V or less of

nominal voltage*

(Initial)

75%V or less of

nominal voltage*

(Initial)

66.7mA

66.7mA

45

45

200mW

200mW

150%V of

nominal voltage

4.5V DC

44.4mA

44.4mA

101.2

101.2

5V DC

40mA

40mA

125

125

6V DC

33.3mA

33.3mA

180

180

9V DC

22.2mA

22.2mA

405

405

12V DC

16.7mA

16.7mA

720

720

24V DC

12.5mA

12.5mA

1,920

1,920

300mW

300mW

120%V of

nominal voltage

Characteristics

Item

Specifications

Contact

Arrangement

2 Form C

Initial contact resistance, max.

Max. 60 m

Ω (By voltage drop 6 V DC 1A)

Contact material

Ag+Au clad

Rating

Nominal switching capacity (resistive load)

1 A 30 V DC, 0.5 A 125 V AC

Max. switching power (resistive load)

30 W (DC), 62.5 VA (AC)

Max. switching voltage

110 V DC,125 V AC

Max. switching current

1 A

Min. switching capacity (Reference value)*

1

10

µA 10mV DC

Nominal operating
power

Single side stable

140 mW (3 to 12 V DC), 200 mW (24 V DC), 300 mW (48 V DC)

1 coil latching

100 mW (3 to 12 V DC), 150 mW (24 V DC)

2 coil latching

200 mW (3 to 12 V DC), 300 mW (24 V DC)

Electrical
characteristics

Insulation resistance (Initial)

Min. 1,000M

Ω (at 500V DC)

Measurement at same location as “Initial breakdown voltage” section.

Breakdown voltage
(Initial)

Between open contacts

750 Vrms for 1 min. (Detection current: 10 mA)

Between contact and coil

1,000 Vrms for 1 min. (Detection current: 10 mA)

Between contact sets

1,000 Vrms for 1 min. (Detection current: 10 mA)

Surge breakdown
voltage (Initial)

Between open contacts

1,500 V (10

×160µs) (FCC Part 68)

Temperature rise (at 20

°C

68

°F

)

Max. 50

°C

(By resistive method, nominal voltage applied to the coil; contact carrying current: 1A.)

Operate time [Set time] (at 20

°C

68

°F

)

Max. 3 ms [Max. 3 ms] (Nominal voltage applied to the coil, excluding contact bounce time.)

Release time [Reset time] (at 20

°C

68

°F

)

Max. 3 ms [Max. 3 ms] (Nominal voltage applied to the coil, excluding contact bounce time.)
(without diode)

Mechanical
characteristics

Shock resistance

Functional

Min. 490 m/s

2

(Half-wave pulse of sine wave: 11 ms; detection time: 10

µs.)

Destructive

Min. 980 m/s

2

(Half-wave pulse of sine wave: 6 ms.)

Vibration resistance

Functional

10 to 55 Hz at double amplitude of 3 mm (Detection time: 10

µs.)

Destructive

10 to 55 Hz at double amplitude of 5 mm

Expected life

Mechanical

Min. 10

8

(at 180 cpm)

Electrical

Min. 2

×10

5

(1 A 30 V DC resistive), Min. 10

5

(0.5 A 125 V AC resistive) (at 20 cpm)

Conditions

Conditions for operation, transport and storage*

2

Ambient temperature: –40

°C to 70°C

–40

°F to 158°F

;

Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)

Max. operating speed (at rated load)

20 cpm

Unit weight

Approx. 1.5 g

.053 oz

1. Maximum switching capacity

2. Life curve

3. Mechanical life

Tested sample: TN2-12V, 10 pcs.

30

100

200

1.0

0.5

0.4

0.3

0.2

Switching voltage,V

Switching current, A

DC load (cos

ϕ=1)

AC load (cos

ϕ=1)

100

10

0

0.5

1.0

Switching current, A

No. of operations,

×

10

4

125 V AC resistive load

30 V DC resistive load

10

100

1,000

10,000

0

10

20

30

40

50

60

70

80

90

100

Ratio against the rated voltage, %V

No. of operations,

×10

4

Max.

Max.

Min.

Min.

Pick-up voltage

Drop-out voltage

All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.

Advertising