Preparation, Notification about the installation site, Preparing the necessary items – Panasonic BM-ET330 User Manual

Page 18: Cable preparation

Advertising
background image

M6

18

Item

Required when installing the mounting
bracket over the wall with the unicorn
anchor

Coaxial cable

UL Listed NEC type CM or
CL2, RG-6/U type

Recommended distance: 20 m
{65.6 ft.} or less

Use

For connection between an external
video-input device and the iris reader

Connect both ends with BNC plugs.

Power cable

Item number/Recommended type

UL style 1015 (AWG 14-18) or
equivalents

Maximum distance: 10 m {32.8 ft.}

Necessary when supplying power from
the external power-supply device to
the iris reader

Solder both ends of the cable with M3
screw clamp terminals.

LAN cable

UL style 1666, CSA-FT4 or equivalents

10 Base-T/100 Base-TX (Category 5)

*1

Necessary for communication between
the iris readers and iris server

Anchor bolt

Preparation

Prepare the following items before the installation. The necessary items and their lengths differ depending on situation.

Preparing the Necessary Items

*

1

Only cables without connector covers are usable.

Notes:

• When you use the alarm output and Wiegand terminals, you need optional cables suited for the connectors of external

devices. Use the UL style 1571 or equivalents, AWG 22 - 16 wire.

• When you use the RS-485 terminals, you need optional twisted pair cables (AWG 22 - 16) suited for the connectors of

external devices.

• It is recommended to use shielded twisted pair cables for the open collector output connectors (!6 - !9). (GND @0 is to be

paired.)*

2

*

2

!6, !9, and @0 are Pin No. Refer to p.16.

Cable Preparation

Power cable (with sealing)

Notification about the Installation Site

This iris reader is limited to indoor use.
Near-infrared light (contained in sunlight, incandescent light and halogen light) are used for iris image capturing by the iris
reader. If the iris reader is installed in a place which receives this light directly, it may cause invalid iris data
enrollment/recognition, as the iris reader cannot capture iris images properly.

Keep the iris reader away from the following. Otherwise, light may affect on the iris reader.

• Outdoor places
• Direct sunlight or light reflection
• Incandescent or halogen lighting
• Places where the iris reader or the user's eyes are directly exposed to light

25 mm {1 in.} or less

Advertising